outofband metadata.md

Configure out-of-band metadata in input stream

There are different types of out-of-band metadata:

To configure out-of-band metadata input stream, follow these steps:

Info: In our example, we consider that you have selected an MPEG-2 TS input type.

  1. From the Input tab, go to the Metadata section then click the Add button. The Metadata selection window displays.

  2. Select a Type.

Example of configuration for SCTE-35 OOB metadata

Info: SCTE-35 OOB can be used for automation (Clock) or when there is no SCTE-35 in the input.

  1. Enter the appropriate values for the following parameter:
  1. Click Ok to save settings and return to the service edition options. The metadata stream is added to the list.

Info: If you selected SCTE-35 OOB metadata, Live Encoder ESAM out-of-band signal interface is now accessible from http://<controller.ip>:8080/api/esam/LiveEncodings/<network_name>.

  1. Save your settings to continue or click Exit to quit without saving.

  2. You can configure the metadata encoding and add the metadata to the output stream.

For ESAM out-of-band, the POIS should perform an HTTP POST request to the following URL: http://<controller.ip>:8080/api/esam/LiveEncodings/<network_name> where:

Info:

Configure SCTE-35 out-of-band metadata input stream

To configure SCTE-35 out-of-band metadata input stream, follow these steps:

Info: In our example, we consider that you have selected an MPEG-2 TS input.

  1. From the Input tab, go to the Out-of-band streams section then click the Add button. The Metadata selection window displays.

  2. Set the Type to SCTE-35 OOB.

Example of configuration for SCTE-35 OOB metadata

Info: SCTE-35 OOB can be used for automation (Clock) or when there is no SCTE-35 in the input.

  1. Enter the appropriate value for the following parameters:

    • Network name
    • Zone identity
    • ESAM server network interface
  2. Click Ok to save settings and return to the service edition options. The metadata stream is added to the list.

Info: If you selected SCTE-35 OOB metadata, Live Encoder ESAM out-of-band signal interface is now accessible from: http://<controller.ip>:8080/api/esam/LiveEncodings/<network_name>.

  1. Save your settings to continue or click Exit to quit without saving.

Configure SCTE-104/IP out-of-band metadata input stream

To configure SCTE-104/IP out-of-band metadata input stream, follow these steps:

Info: In our example, we consider that you have selected an MPEG-2 TS input.

  1. From the Input tab, go to the Out-of-band streams section, click the Add button. Metadata selection window displays.

  2. Set the Type to SCTE-104 / IP OOB.

Example of configuration for SCTE-104/IP out-of-band metadata

  1. Enter the appropriate value for the following parameters:

    • DPI PID index
    • SCTE-104 server network interface (if not already configured in the General tab).
  2. Click Ok to save settings and return to the service edition options. The metadata stream is added to the list.